227398

KEEBOMED Vet Monitor Biolight BLT M7000

From
$98.99
Learn More
Check Store Availability

We don't have enough stock on hand.

Adding to cart… The item has been added
Added to Cart

7" M7000 BLT Biolight Veterinary Monitor

Biolight BLT M7000 is FDA approved. Use to monitor patients ECG, respiration-breathing, NIBP, SPO2, temperature, and heart rate. Comes with specific animal software for canine, feline, equine, and bovine. Recommended for small animals like cats and dogs for heart monitoring.

Features

  • 7" TFT LCD display - high resolution
  • Built-in rechargeable battery
  • User-Friendly operational window
  • 60 seconds full disclosure of ECG playback
  • 48 hours tabular and graphic trends and data storage
  • Digital SPO2, high capacity against interference of ESU, motion and low infusion
  • Isolated against defibrillation effect
  • Wireless or wire communicable with central station system
  • Parameter: 5 Lead ECG, RESP, Digital SPO2, NIBP, TEMP

Specifications

  • Safety: IEC60601 (GB9706)
  • Dimension: 256mm (W) x 209mm (H) x 185mm (D)
  • Weight: 4 Kgs (with battery)
  • Power Supply: 100~240V; AC: 47~ 63 Hz 12 VDC
  • Alarm Indication: Visual and audible alarm

ECG 

  • Has Leads: I, II, III, aVR, aVL, aVF, Cx
  • M7000 has Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto
  • Accuracy: ±1BPM

NIBP 

  • Method: Automatic oscillometric
  • Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
  • Measurement : Systolic pressure/diastolic pressure/mean
  • Range: Adult: 10-270mmHg
  • Pediatric: 10-235mmHg
  • Neonate: 10-135mmHg
  • Unit: mmHg / Kpa selectable
  • Auto Measurement: 1, 2, 3, 4, 5, 10, 15, 20, 30, 45, 60, 90 minutes, 2, 4, 8, 12 hours
  • 600 groups of NIBP measuring data review

RESP

  • Method: Impedance Measurement
  • Measuring Range: 0-120bpm
  • Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
  • Apnea alarm: Available
  • BLT Digital SPO2 (Pulse Oximetry)
  • Range: 0-100%
  • Accuracy: ±2% (70%~100%); ±3%(35%~ 69%) Unspecified (0~34%)
  • Range & Accuracy of Pulse Rate: 25~250BPM ±1BPM

TEMP

  • Channel: 2 channels
  • Range: 0~50°
  • Unit: Celsius, Fahrenheit
  • Resolution: 1mmHg
  • Accuracy: ±0.1°(25°~50°)
  • Humidity - Operation: 10%~95%, non condensing
  • Storage / Transportation: 0%~93% non condensing
  • Atmospheric Pressure: Operation: 700~1060hPa
  • Storage / Transportation: 500~1060hPa
  • Standard configuration: ECG , Heart Rate, RESP, NIBP, SPO2, RR, Temperature, Battery
  • Option: 2-TEMP, Thermal Recorder, Nellcor SPO2

WASHING INSTRUCTIONS:

Machine wash separately in cold water on a gentle cycle. Tumble dry separately on low heat. Add QE Home Wool Dryer Balls to reduce wrinkles and increases drying efficiency. Touch up with a low heat iron as needed. Do not bleach or dry clean.