305921

SINO K SNP9000N Patient Monitor with Multi parameter to Monitor Vital Sign ECG, SpO2,NIBP, TEMP,RESP,PR,HR 12.1 Inch

From
$90.00
Learn More
Check Store Availability

We don't have enough stock on hand.

Adding to cart… The item has been added
Added to Cart

Features &Benefits:

  1. 11” color TFT display, high resolution:800×600dpi;
  2. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob;
  3. Real time S-T segment analysis,and ARR analysis;
  4. SpO2 Pitch Tone Variationand Drug Dose Calculation;
  5. Parameter waveform and characters color selectable
  6. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
  7. Standby mode for Energy savingand suspend monitoring;
  8. 7-lead ECG waveforms display in phase;
  9. Capture dynamic waveforms;
  10. Built-in rechargeablelithium battery, and battery volume checking,
  11. AC power checking
  12. Efficient resistance to interference of defibrillator and HF knife;
  13. SINNOR F-6 SpO2 technology, VS NELLCORaccuracy;
  14. Networking capacity and TCP/IP networking platformenable abundant future upgrade
  15. Time delay switch-offfunction keep the monitor data restart monitor;
  16. Complete and flexible mounting solution for transportation and in-patient monitoring
  17. Can do with SpO2, ECG, NIBP, Temp, HR, PR, AG, IBP, EtCO2, N2O. with our Strong R &D team.
  18. SpO2 can work well In the condition of the low perfution of the patient
  19. Can work in ICU, OR, ER.
  20. Permanent suspensionof the Alarm with one button


Standard parameters: 5-lead ECG, SpO2,NIBP, TEMP,RESP,PR,HR.

Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,




Performance Specifications

Display:       12.1”color TFT

Rolling and refreshing waveform display

Resolution: 800×600

Multi display selectable including:

Large-font display

Trend coexist display

OxyCRG dynamic view display.

Bed-to-bed view display

Trace:             9 waveforms(7 ECG, 1 SPO2 and 1 RESP)

Sweep speed:12.5mm/s,25mm/s,50mm/s

Indicator:          Power/battery indicator light

QRS beep and alarm sound

Battery:           Rechargeable lead acid cell, 12v/4AH

Max.24 hour for charging, 4 hours for continue working

Trend:             Parameter graphic and tabular trends:

5s/piece,8 hours;

1min/piece,168 hours(24hour×7days)

5min/piece,1000 hours.


Storage:           NIBP: 1000 groups

Alarm: 200 groups

Full disclosure waveforms: 3600S

SD card external storage

Alarm:         User-adjustable High, Medium and Low limits 3-level

 Audible and visual alarm

Networking:        Connected to central monitoring system

TCP/IP netting platform

Recorder:         Build-in, thermal array

Plethysmogram caveform:2 channels

Record mode: manual, on alarm, time-defined

Recording width: 50mm

Printing speed: 50mm/s

Recording type:    Frozen waveform record

NIBP recall record

Trend table record

Alarm record

Fixed -time record


Standard parameter:

ECG:


Lead mode: 5 –lead(R,L,F,N,C)

Lead selection : I,II,III,avR,avL,avF,V

Waveform:     3 and 7 channel selectable

Gain selection: 0.5mm/mv,1mm/mv,2mm/mv

Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s

Heart rate range:    Adult: 15~300bpm;

Neonate/pediatric:15~350bpm

Accuracy: +1bpm or +1%,whichecer is greater

Resolution:     1bpm

Filter: surgery mode:1~20Hz

monitor model:0.5~40Hz

Diagnostic mode:0.05~130Hz

Scaling signal: 1mv,+3%

Protection:       withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

Alarm range: 15~350bpm

S-T segment detecton:

Measurement range:  2.0mV~+2.0mV                         


 Alarm Range:         -2.0mV~ +2.0mV

Accuracy:            -0.8mV ~+0.8Mv

Error:               +0.02Mv

 

Arrhythmia analysis: YES


SPO2

Measurement range:        0~100%

Resolution:                1%

Accuracy:                 +2%(70-100%);0-69% unspecified

Alarm range               0~100%

Pluse Rate:                

range:        20~300bpm

Resolution:   1bpm

Error:        +1bpm or +2%,whichever is greater


NIBP

Method:                   Digital Automatic oscillometric

Operation mode :            Manual/Automatic/continuous

Auto measurement time:      Adjustable(1~480min)

Measurement Unit:          mmHg/Kpa selectable

Measurement types:         Systolic, Diastolic, Mean  

Measurement tange:

Range of Systolic pressure:    Adult: 40~270mmHg

Pediatric: 40~220mmHg

Neonate: 40~135mmHg

Range of mean pressure:      Adult: 20~235mmHg

Pediatric: 20~165mmHg

Neonate: 20~110mmHg

Range of diastolic pressure:   Adult: 10~215mmHg

Pediatric: 10~150mmHg

Neonate :10~100mmHg

Over-pressure protection:     Double safety protection

Resolution:                 1 mmHg

Alarm:                    Systolic.Diastolic,Mean



RESPIRATION

Method:                     Thoracic impedance

Measurement range:           Adult:7~120rpm;

Neonate/Pediatric:7~150rpm

Apnea alarm:                 YES,10~40s

Resolution:                   1rpm

Accuracy:                    +2rpm



TEMPERATURE

Compatible probe:             YSI or CYF

Measurement range:           5~50℃

Resolution :                   0.1℃

Accuracy:                    +0.1℃

Refreshing time:               about 1

Average measuring time:        <10s



Optional parameters:


IBP

Channel: 2 channels

Range: -50-300mmHg

Resolution: 1mmHg

Accuracy: ±4mmHg(±4%)

Unit: mmHg, Kpa

Converter Sensitivity: 5mV/V/mmHg

Transducer sites: ART/PA/CVP/LAP/RAP/ICP


EtCO2( Sidertream CO2)

Measurement range:   0~99mmHg

Accuracy:   +2mmHg (0~40mmHg)

Sampling Range:   100ml/min

Sampling rate accuracy:   15%

Respiration rate:   0~120rmp

Respiration accuracy:  +2rmp (0~70rmp)

+5rmp (>70rmp)

Respiration time:   <240msec (10% to 90%)

Delay time:  <2s

 

EtCO2 (mainstreaam CO2)

Method:   Infrared Spectrum

Range:   0.0-10% (0~76%)

Resolution:   1mmHg (0.1%)

Accuracy:   <5%(±4.0 mmHg)

         Or<10%(of Readings)


Recorder:     

Build-in, thermal array

Plethysmogram caveform:2 channels

Record mode: manual, on alarm, time-defined

Recording width: 50mm

Printing speed: 50mm/s

Recording type:  Frozen waveform record

NIBP recall record

Trend table record

Alarm record

Fixed -time record




Miscellaneous

 

Satety:              

Safety level: Class I, type CF


Dimendion and Weight

Dimendion:      28*42*48cm         

G.Weight:        <6.5KS


Operation Environment

Temperature:    Working 0~+40℃

Transportation and storage –20~+60℃

Humidity:       working≤85%

Transportation and storage≤93%

Power:          AC 100-240,50/60Hz

Patient range:    Neonate,pediatric,and adult patients


 

Accessories supplies

(1) 5 lead ECG cable  

(2) 1 spo2 probes  

(3) 1 NIBP prbe  

(4) 1 temp probe

(5)1 ground connecting liner  

(6) Chest electrode (10pcs/set)

WASHING INSTRUCTIONS:

Machine wash separately in cold water on a gentle cycle. Tumble dry separately on low heat. Add QE Home Wool Dryer Balls to reduce wrinkles and increases drying efficiency. Touch up with a low heat iron as needed. Do not bleach or dry clean.

Reviews